Tpcm™ 7000 AND MaxAir™ Vent Panels for GPUs and TPUs at Hyperscale Data Centers

April 28, 2025, 3:02 pm

Tpcm™ 7000 AND MaxAir™ Vent Panels for GPUs and TPUs at Hyperscale Data Centers

Discover how Laird Technologies transformed the hyperscale data centers of one of its customers using its innovative solutions. Hyperscale data centers that support AI workloads are grappling with some serious challenges, particularly when it comes to managing heat from powerful integrated circuits while also minimizing electromagnetic interference (EMI) in dense PCB designs. If these issues aren't tackled and resolved, they can deteriorate performance and inflate operating costs. 

Laird helped resolve these issues for the customer’s data center/AI infrastructure. The first customer-chosen solution was Laird™ branded MaxAir™ vent panels, which enhance airflow, provide EMI shielding, and are resistant to dents and damage. The second solution was introducing Laird™ branded Tpcm 7000 phase change material to effectively manage heat. This innovative material offers industry-leading lowest thermal resistance. The two solutions not only boosted performance and reliability and aided compliance but also made installation and scaling much easier. Owing to these innovations, the customer’s AI infrastructure was able to deliver outstanding performance. 

Read our case study here. 

 

TPCM7000 AND MAXAIR™ VENT PANELS FOR GPUS AND TPUS AT HYPERSCALE DATA CENTERS

 

Abstract 

As AI-driven workloads continue to expand, hyperscale data centers face growing challenges in thermal management and electromagnetic interference (EMI). This application note explores how a hyperscale client leveraged Laird’s TPCM7000 phase change material and MaxAir™ vent panels to enhance cooling efficiency, reduce EMI, and improve overall data center reliability. Key design considerations, material specifications, and implementation best practices are covered to help engineers optimize similar high-performance computing environments. 

 

Introduction 

The client’s hyperscale data centers support AI applications that demand ever-increasing compute power. GPUs and TPUs generate thermal loads exceeding 500 watts per chip, necessitating highly efficient heat dissipation solutions. Additionally, high-speed processors in dense server racks introduce EMI risks, impacting signal integrity and compliance with industry regulations. 

Traditional cooling and EMI shielding methods presented limitations, including space constraints, insufficient heat dissipation, and complex installation requirements. The tech giant required advanced material solutions that could efficiently manage heat, maintain signal integrity, and ensure compliance without adding excessive bulk or complexity. 

Laird, a leader in materials science for thermal management and EMI shielding, provided two key innovations to address these challenges: TPCM7000 phase change material for high-efficiency heat dissipation and MaxAir™ vent panels for optimized airflow and EMI suppression.

 

Technical Details 

 
TPCM7000 Phase Change Material

TPCM7000 is a high-performance thermal interface material (TIM) designed to enhance heat dissipation in AI accelerators. This advanced phase change material: 

Offers high thermal conductivity for improved cooling efficiency. 

Forms ultra-thin bondlines to reduce thermal resistance. 

Features a non-silicone formulation for enhanced long-term stability. 

Provides excellent wetting properties to minimize air gaps and pump-out.

 

TPCM7000 Specifications

 

Parameter                                                                                              Value                                                                                                     
Thermal Conductivity   7.5 W/mK
Thermal Resistance (10 psi)0.10°C-cm2/W
Thermal Resistance (50 psi) 0.06°C-cm2/W
Dielectric Constant 31.54 @ 1MHz
Volume Resistivity  5.4x101 μ Ω-cm
Operating Temperature -40°C to 150°C
Phase Change Temperature 50°C - 70°C
Minimum Bondline Thickness 35μm

 

MaxAir™ Vent Panels 

MaxAir™ vent panels are frameless EMI shielding solutions that: 

Maximize airflow in dense server environments. 

Reduce energy consumption by improving cooling efficiency. 

Provide lightweight, durable EMI shielding for high-frequency signals. 

Feature a press-fit installation process, eliminating the need for fasteners.

 

MaxAir™ Vent Panel Specifications

 

Parameter                                                                                              Value                                                                                                     
Shielding Effectiveness Up to 60 dB (200 MHz to 10 GHz)
Cell Sizes2.5mm, 6.0mm
Standard Thickness6.4mm, 12.7mm
ComplianceUL94 V0, Halogen-free (IEC 61249-2-21)

 

 

Design Considerations 

 
Thermal Management Factors 

Component Placement: Ensuring direct thermal interface contact with heat-generating chips. 

Pressure Optimization: Applying uniform force to minimize bondline thickness and enhance heat transfer. 

Long-Term Stability: Selecting materials with resistance to pump-out and degradation under high-power cycling.

 

EMI Shielding Factors

Minimizing Airflow Restrictions: Designing vent panels that balance EMI shielding and cooling efficiency. 

Material Selection: Using lightweight, high-durability materials for ease of handling and long-term reliability. 

Installation Efficiency: Implementing press-fit designs to reduce assembly time and complexity

 

Application Examples 

The customer integrated Laird’s solutions across multiple generations of its AI infrastructure: 

TPCM7000 replaced previous TIM solutions to improve heat dissipation, allowing GPUs and TPUs to sustain peak performance without thermal throttling. 

MaxAir™ vent panels replaced traditional aluminum honeycomb coverings, increasing airflow efficiency and reducing installation complexity.

 

Performance Gains

 

Improvement                                                                                         Impact                                                                                                  
Lower Thermal Resistance Enhanced heat dissipation and stable GPU/TPU performance
Optimized AirflowReduced cooling energy requirements
EMI Shielding EfficiencyImproved signal integrity and compliance
Reduced Installation ComplexityFaster deployment and maintenance

 

Implementation and Best Practices 

TPCM7000 Application: Ensure surfaces are clean before application, apply uniform pressure, and allow for proper phase transition during operation. 

MaxAir™ Installation: Measure and prepare openings accurately for precise fitment, use conductive perimeter gaskets for effective EMI shielding, and optimize positioning for maximum airflow.

System Integration: Regularly monitor thermal and EMI performance, and adjust server layouts to maintain efficiency as AI infrastructure scales.

 

Conclusion 

Laird’s TPCM7000 and MaxAir™ solutions provided its data-center client with effective thermal management and EMI shielding solutions, enabling enhanced performance, reliability, and scalability in AI-driven data centers. By leveraging advanced materials and optimized designs, The customer successfully addressed the increasing thermal loads and EMI challenges of next-generation AI accelerators. For engineers designing high-performance computing environments, Laird’s materials offer proven, scalable solutions to manage heat and EMI effectively. To learn more or request product samples, contact Laird’s engineering team.

 

 

 

 

 

Copyright © 2025, Laird Technologies, Inc. DuPont™, the DuPont Oval Logo, Laird™, the Laird Logo, and all trademarks and service marks are owned by DuPont de Nemours, Inc., Laird Technologies, Inc., or their affiliated companies. All rights reserved.